Three-phase voltage stabilizer Ampere U 12-3/32 v2.0 is designed to operate in three-phase electrical networks with voltage fluctuations from 145 to 275V. In this range, the device is guaranteed to deliver a voltage at the output within 220 ± 3.5%, which is ensured through the use of 12 stabilization steps. The total rated power of this model is 21 kW (7 kW per phase), which corresponds to the operating current of the 32A circuit breaker on it.

The features of this stabilizer include floor-standing design, independent operation of each of the phases, the presence of electronic transit (bypass), silent operation due to the use of thyristors as power switches.

Stabilizer Ampere U 12-3/32 v2.0 has the ability to manually adjust the lower shutdown threshold (60-135V). This function is in demand for a load with high inrush currents, at startup of which a strong voltage drop and emergency shutdown of the stabilizer are possible. When this option is activated, the stabilizer will make it possible to start any engine or pump within a minute, even if the voltage drops to 60V in the network.

It is recommended to install and operate the Ampere U 12-3/32 v2.0 stabilizer in dry and heated rooms. The connection is made to the existing wiring through the terminal block, which is located in the upper part of the housing under the cover.

Operating current, A 3 × 32
Rated power, kVA / kW 22
Number of stabilization steps 12
Key type thyristor
The efficiency of the stabilizer is not lower,% 97
Active power consumption at idle, no more, W 35
Nominal output voltage, V 220
Minimum operating input voltage, V 100
Maximum input operating voltage, V 295
Adjustment of the lower threshold of shutdown, V 60-135
Stabilization range, V 145-275
Accuracy in the stabilization range,% 3.5
Response time to changes in input voltage, ms 20
Power supply frequency, Hz 45-65
Input Current and Apparent Power Measurement yes
Short-circuit and overload current limitation input circuit breaker with C-characteristic electromagnetic protection
Electronic Bypass yes
Network and Stabilizer Condition Analyzer yes
Duplicate overvoltage protection yes
Microcontroller control yes
Input choke yes
Output choke no
Overheating protection yes
Minimum cable cross-section for connection, mm² 6
Maximum cross-section of cable conductors for connection, mm² 30
Forced Cooling two speed fan
Overall dimensions, mm, no more 725x480x310
Weight, kg, no more 75
Warranty, years 7
Back to Top