Search

Single-phase voltage stabilizer AMPERE-R U 16-1/25 v2.0

Compare

Single-phase voltage stabilizer “Amper-R 16” (extended) is designed to operate in electrical networks with voltage fluctuations from 120 to 275V. In this range, the device is guaranteed to output a voltage within 220 ± 3.5%, which is ensured through the use of 16 stabilization steps.

The range of all listed Amperes in terms of power can be 5.5, 7, 9, 11, 14 and 18 kW, which corresponds to an operating current of 25, 32, 40, 50, 63 and 80A, respectively.

The features of this stabilizer include silent operation due to the use of triacs (thyristors) as power switches and the presence of electronic transit (bypass).

The Ampere stabilizer of 16 steps has the ability to manually adjust the lower shutdown threshold (60-135V). This function is in demand for a load with high inrush currents, at startup of which a strong voltage drop and emergency shutdown of the stabilizer are possible. When this option is activated, the stabilizer will make it possible to start any engine or pump within a minute, even if the voltage drops to 60V in the network.

It is recommended to install and operate the Ampere stabilizer in dry and heated rooms. It is recommended to mount the wall in a vertical position (fans upwards), leaving 10-15cm at the top and bottom for cooling. The connection is made to the existing wiring through the terminal block.

Operating current, A 25
Rated power, kVA / kW 5.5
Number of stabilization steps 16
Key type triac
The efficiency of the stabilizer is not lower,% 98
Active power consumption at idle, no more, W 35
Nominal output voltage, V 220
Minimum operating input voltage, V 90
Maximum input operating voltage, V 295
Manual adjustment of the lower shutdown threshold, V 60-135
Stabilization range, V 120-275
Accuracy in the stabilization range,% 3.5
Response time to changes in input voltage, ms 20
Power supply frequency, Hz 45-65
Input Current and Apparent Power Measurement yes
Short-circuit and overload current limitation input circuit breaker with B-characteristic electromagnetic protection
Electronic Bypass yes
Network and Stabilizer Condition Analyzer yes
Duplicate overvoltage protection yes
Microcontroller control yes
Input choke yes
Output choke no
Overheating protection yes
Minimum cable cross-section for connection, mm² 4
Maximum cross-section of cable conductors for connection, mm² 30
Forced Cooling two speed fan
Overall dimensions, mm, no more 460х275х175
Weight, kg, no more 21
Warranty, years 7
Back to Top
Product has been added to your cart