Single-phase voltage stabilizer Ampere U 12-1/40 v2.1 (standard) is designed to operate in electrical networks with voltage fluctuations from 145 to 275V. In this range, the device is guaranteed to deliver a voltage at the output within 220 ± 3.5%, which is ensured through the use of 12 stabilization steps. The rated power of this model is 9 kW, which corresponds to an operating current of the circuit breaker of 40 A on it.

The features of this stabilizer include a double LED screen, a linear loading strip, the presence of electronic transit (bypass), a convenient location of the terminal block for connection on the back of the case, silent operation due to the use of triacs as power switches.

Stabilizer Ampere U 12-1/40 v2.1 has the ability to manually adjust the lower shutdown threshold (60-135V). This function is in demand for a load with high inrush currents, at startup of which a strong voltage drop and emergency shutdown of the stabilizer are possible. When this option is activated, the stabilizer will make it possible to start any engine or pump within a minute, even if the voltage drops to 60V in the network.

It is recommended to install and operate the Ampere U 12-1/40 v2.1 stabilizer in dry and heated rooms. It is recommended to mount the wall in a vertical position (fans up), leaving 10-15 cm at the top and bottom for cooling. The connection is made to the existing wiring through the terminal block.

Operating current, A 40
Rated power, kVA / kW 9.0
Number of stabilization steps 12
Key type triac
The efficiency of the stabilizer is not lower,% 98
Active power consumption at idle, no more, W 35
Nominal output voltage, V 220
Minimum operating input voltage, V 100
Minimum operating input voltage in bypass mode, V 120
Maximum operating input voltage in bypass mode, V 265
Maximum input operating voltage, V 295
Stabilization accuracy,% 3.5
Response time to changes in input voltage, ms 20
Power supply frequency, Hz 45-65
Input Current and Apparent Power Measurement yes
Short-circuit and overload current limitation input circuit breaker with B-characteristic electromagnetic protection
Electronic Bypass yes
Network and Stabilizer Condition Analyzer yes
Duplicate overvoltage protection yes
Microcontroller control yes
Input choke yes
Output choke no
Overheating protection yes
Minimum cable cross-section for connection, mm2 6
Maximum cross-section of cable conductors for connection, mm2 30
Forced Cooling two speed fan
Overall dimensions, mm, no more 460х275х165
Weight, kg, no more 21
Warranty, years 3